Application note
Relationship between radiated EMI measurable lower level and antenna gain

Lower levels of radiated EMI noise can be measured by using a high gain antenna. Application By using a high gain antenna, lower levels of noise can be measured in […]

Read more
Application note
Conducted EMI Test System combining MSA series and another maker’s LISN

Application In MR2150, a pre-compliance system for conducted EMI tests using a spectrum analyzer or a signal analyzer for EMI measurement manufactured by MICRONIX, not only MPW201B manufactured by MICRONIX […]

Read more
Application note
Antenna selection for on-site measurement of radiation emission

Difference in measurement result and selection method depending on antenna difference. Application In the pre-compliance tests of radiated EMI (emission), it is important to select the receiving antenna and the […]

Read more
Application note
Measures for radiation immunity test by small loop antenna

EMS simple measurement Application Simple radiation immunity test of 80 MHz to 500 MHz, 30 V/m can be performed for preliminary evaluation before bringing the EUT to the EMC test […]

Read more
Application note
On-site measurement of radiated emission

Here is an example of on-site measurement of radiated emission at a site without a shield environment. Application This is on-site measurement system of radiated emission for pre-compliance. This is […]

Read more
Application note
Simple low frequency radiation system

By limiting frequency and radiation level, it’s possible to build low-cost low-frequency radiation system. Application By limiting frequency and radiation level, it’s possible to build low-cost low-frequency radiation system. It […]

Read more
Application note
Simple radiated emission measurement

Low cost and simple radiated emission measurement by spectrum / signal analyzer and biconical antenna. Application If the environmental noise is sufficiently smaller than the radiated emission limit level, it […]

Read more
Application note
An EMI estimation method by simple evaluation of radiated emission

Simple and low-cost EMI estimation by using spectru m/signal analyzer(338E/438E/538E/558E) Application Precompliance EMI test system MR2300 using spectrum/sign al analyzer (338E/438E/538E/558E) and anechoic box has superior cost performance. This paper […]

Read more
Application note
Measures against radiated immunity test using electric field probe

Pre-compliance EMS(immunity) testing Application Instead of carrying an equipment to be measured (EUT) to the EMC test site and accomplishing the immunity test many times, it is possible to perform […]

Read more
Application note
Easy setup guide to test environment for conducted EMI

Implementation of low-cost test environment for conducted EMI with practical measurement accuracy by using MR2150 Application MR2150 consisting of signal analyzer, LISN and PC software is a precompliance test system […]

Read more