{"id":6039,"date":"2005-03-20T12:10:24","date_gmt":"2005-03-20T03:10:24","guid":{"rendered":"https:\/\/micronix-jp.com\/english\/?post_type=product&#038;p=6039"},"modified":"2024-04-12T09:07:29","modified_gmt":"2024-04-12T00:07:29","slug":"discontinued-productdsrc-ask%ef%bc%8bqpsk-etc-inspection-system-for-obe-production-me9000","status":"publish","type":"product","link":"https:\/\/micronix-jp.com\/english\/products\/etc\/me9000.html","title":{"rendered":"[Discontinued Product]DSRC ASK\uff0bQPSK ETC Inspection System For OBE Production ME9000"},"content":{"rendered":"<div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block\"><a href=\"\/eng\/file-download\/catalog\/me9000-eng.pdf\" class=\"vk_button_link btn has-background has-vk-color-primary-background-color btn-lg btn-block\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><i class=\"fas fa-file-pdf vk_button_link_before\" aria-hidden=\"true\"><\/i><span class=\"vk_button_link_txt\">Download catalog<\/span><\/div><\/a><\/div><div class=\"wp-block-vk-blocks-table-of-contents-new vk_tableOfContents vk_tableOfContents-style-default tabs\"><div class=\"tab\"><div class=\"vk_tableOfContents_title\">\u76ee\u6b21<\/div><input type=\"checkbox\" id=\"chck1\"\/><label class=\"tab-label vk_tableOfContents_openCloseBtn button_status button_status-close\" for=\"chck1\"><\/label><ul class=\"vk_tableOfContents_list tab_content-close\"><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-2\"><a href=\"#vk-htags-e3d55910-826d-4f6f-8117-00040addf477\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">1. <\/span>Features<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-3\"><a href=\"#vk-htags-88455c6b-8f49-42e6-b53b-513ae26c0efd\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">1.1. <\/span>Based on ARIB STD-T75 and ARIB TR-T16.<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-3\"><a href=\"#vk-htags-13f669ad-a5f7-4b80-a0b0-92b8d8a4b815\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">1.2. <\/span>Equipped with two modulations of ASK and QPSK.<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-3\"><a href=\"#vk-htags-ba8dadbc-c595-4a23-90ca-1f1c2fbf54b7\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">1.3. <\/span>Supports Profile 9 to 12 in ARIB STD-T75.<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-3\"><a href=\"#vk-htags-d90f5a21-180a-441c-8ca4-8ddb440f6029\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">1.4. <\/span>Basic operation test, Dynamic motion test and Wireless system test can be performed.<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-3\"><a href=\"#vk-htags-52cf6e90-bc02-4d14-8611-c1b76669f366\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">1.5. <\/span>Wireless system test<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-3\"><a href=\"#vk-htags-48b44f98-75ca-48b3-801a-ebbbb6f8b634\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">1.6. <\/span>PC software MAS960<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-3\"><a href=\"#vk-htags-c9f12d0c-ac12-465e-bfa4-01faa0f4bb46\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">1.7. <\/span>The amplitude level calibration and the self-check of a system can be performed.<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-2\"><a href=\"#vk-htags-71f3b412-3c9c-4122-ac0f-087b77f58ad5\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">2. <\/span>Specification<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-2\"><a href=\"#vk-htags-e7e7fa6c-9787-4589-a2c8-2f2c14360fe5\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">3. <\/span>Library<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-3\"><a href=\"#vk-htags-91f1e49b-05eb-4997-9999-4854b737360b\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">3.1. <\/span>Products Catalog<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-3\"><a href=\"#vk-htags-282b78be-76c3-4640-9a1a-e5c57390daae\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">3.2. <\/span>Technical report<\/a><\/li><\/ul><\/div><\/div><h2 class=\"wp-block-heading\" id=\"vk-htags-e3d55910-826d-4f6f-8117-00040addf477\">Features<\/h2><h3 class=\"wp-block-heading\" id=\"vk-htags-88455c6b-8f49-42e6-b53b-513ae26c0efd\">Based on ARIB STD-T75 and ARIB TR-T16.<\/h3><h3 class=\"wp-block-heading\" id=\"vk-htags-13f669ad-a5f7-4b80-a0b0-92b8d8a4b815\">Equipped with two modulations of ASK and QPSK.<\/h3><h3 class=\"wp-block-heading\" id=\"vk-htags-ba8dadbc-c595-4a23-90ca-1f1c2fbf54b7\">Supports Profile 9 to 12 in ARIB STD-T75.<\/h3><p>It is especially important for OBE equipped with both of ASK and QPSK modulation to be able to be tested on the condition of Profile 11.<\/p><h3 class=\"wp-block-heading\" id=\"vk-htags-d90f5a21-180a-441c-8ca4-8ddb440f6029\">Basic operation test, Dynamic motion test and Wireless system test can be performed.<\/h3><h3 class=\"wp-block-heading\" id=\"vk-htags-52cf6e90-bc02-4d14-8611-c1b76669f366\">Wireless system test<\/h3><p>Modulation factor (ASK), modulation accuracy (QPSK), receiving sensitivity and opening eye ratio (ASK) measurement can be performed in wireless system test besides seven test items (excluding \"signal transmission speed\") relating to the technical regulations conformity certification stipulated in the radio law.<\/p><h3 class=\"wp-block-heading\" id=\"vk-htags-48b44f98-75ca-48b3-801a-ebbbb6f8b634\">PC software MAS960<\/h3><p>It is used to control this ME9000 system.<\/p><h3 class=\"wp-block-heading\" id=\"vk-htags-c9f12d0c-ac12-465e-bfa4-01faa0f4bb46\">The amplitude level calibration and the self-check of a system can be performed.<\/h3><h2 class=\"wp-block-heading\" id=\"vk-htags-71f3b412-3c9c-4122-ac0f-087b77f58ad5\">Specification<\/h2><p>Applicable test items<\/p><p>The arbitrary items from \u2460 to \u2466 in the table below can be selected, and they can be brought together as one system.<br>For instance, \u2460 and \u2461 are selected in the initial development phase and \u2460 , \u2461 , \u2462 and \u2466 are selected in the production line.<br>The test can be done by both of the air connection and the coaxial connection.<br>In the test by the air connection, the shield box ME8661A equipped with a transmission antenna and a receiving antenna is needed.<br>Moreover, the personal computer and the PC software MAS960 are necessary at all the test items.<\/p><figure class=\"wp-block-flexible-table-block-table\"><table class=\"\"><tbody><tr><th colspan=\"2\" style=\"width:50%\">Test item<\/th><th>Contents<\/th><\/tr><tr><td rowspan=\"2\">\u2460Basic operation test<\/td><td>profile test<\/td><td><ul>\n<li>Communication<\/li>\n<li>Execute &lt;2-1-1&gt; to &lt;2-1-22&gt; of ARIB TR-T16<\/li>\n<\/ul><\/td><\/tr><tr><td>Protocol test<\/td><td>\n<ul>\n<li>Execute profile 9 to 12<\/li>\n<\/ul>\n<\/td><\/tr><tr><td>\u2461Dynamic motion test<\/td><td>&nbsp;<\/td><td><ul>\n<li>Execute &lt;2-2-1&gt; to &lt;2-2-3&gt; of ARIB TR-T16<\/li>\n<li>MAT800 and average power meter are used.<\/li>\n<\/ul><\/td><\/tr><tr><td rowspan=\"7\">\u2462Wireless system test \uff08items relating to TRCC)<\/td><td>Antenna power<\/td><td rowspan=\"7\"><ul>\n<li>Measured by Spectrum analyzer.<\/li>\n<li> The carrier frequency is measured by a frequency counter function of Spectrum analyzer. <\/li>\n<li>The signal transmission rate can not be measured. <\/li>\n<li>The calibration is done by MAT800 and average power meter.<\/li>\n<\/ul><\/td><\/tr><tr><td>Carrier frequency<\/td><\/tr><tr><td>Occupied bandwidth<\/td><\/tr><tr><td>Carrier off leakage power<\/td><\/tr><tr><td>Adjacent channel power<\/td><\/tr><tr><td>Spurious radiation strength<\/td><\/tr><tr><td>Radio wave strength emitted subordenately<\/td><\/tr><tr><td rowspan=\"4\">Wireless system test (items relating to TRCC)<\/td><td>\u2463Modulation factor<\/td><td><ul>\n<li>Only ASK. <\/li>\n<li>MMD850 and digital oscilloscope are used.<\/li>\n<\/ul><\/td><\/tr><tr><td>\u2464Modulation accuracy<\/td><td><ul>\n<li>Only QPSK.<\/li>\n<li>Spectrum analyzer with modulation accuracy measurement function is used.<\/li>\n<\/ul><\/td><\/tr><tr><td>\u2465Receiving sensitivity<\/td><td><ul>\n<li>Through the sequence in which ME9010 transmits FCMC and receives ACTC correctly, the minimum transmission level is measured.<\/li>\n<li>MAT800 and average power meter are used.<\/li>\n<\/ul><\/td><\/tr><tr><td>\u2466Opening eye ratio<\/td><td><ul>\n<li>Only ASK.<\/li>\n<li>MMD850 and digital oscilloscope are used.<\/li>\n<\/ul><\/td><\/tr><\/tbody><\/table><\/figure><h2 class=\"vk_block-margin-lg--margin-top wp-block-heading\" id=\"vk-htags-e7e7fa6c-9787-4589-a2c8-2f2c14360fe5\">Library<\/h2><h3 class=\"vk_block-margin-lg--margin-top wp-block-heading\" id=\"vk-htags-91f1e49b-05eb-4997-9999-4854b737360b\">Products Catalog<\/h3><ul class=\"wp-block-list\"><li><a href=\"\/eng\/file-download\/catalog\/pdf\/me9000-eng.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">ETC\/DSRC inspection system ME9000 Catalog(PDF)<\/a><\/li>\n\n<li><a href=\"\/eng\/file-download\/catalog\/pdf\/DIGEST_eng.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">MICRONIX Products DIGEST Catalog (PDF3.75MB)<\/a><\/li><\/ul><h3 class=\"vk_block-margin-lg--margin-top wp-block-heading\" id=\"vk-htags-282b78be-76c3-4640-9a1a-e5c57390daae\">Technical report<\/h3><ul class=\"wp-block-list\"><li><a href=\"\/english\/tech\/technology\/me-HeatRayReflectionGlass_e.html\" target=\"_blank\" rel=\"noopener noreferrer\">Inspection of heat ray reflection glass<\/a><\/li>\n\n<li><a href=\"\/english\/tech\/technology\/MAT800B_D.html\" target=\"_blank\" rel=\"noopener noreferrer\">MAT800B\/D technical data of VSWR and Attenuation.<\/a><\/li>\n\n<li><a href=\"\/english\/tech\/technology\/MAT800_810_application-E.html\" target=\"_blank\" rel=\"noopener noreferrer\">Air simulation for wireless communication<\/a><\/li><\/ul><div class=\"wp-block-cover is-light vk_block-margin-xl--margin-top\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-white-background-color has-background-dim\"><\/span><img class=\"wp-block-cover__image-background wp-image-8105\" alt=\"\" src=\"https:\/\/micronix-jp.com\/wp-content\/uploads\/2022\/11\/contact_cta_cover.png\" data-object-fit=\"cover\"\/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><p class=\"has-text-align-center has-huge-font-size\"><strong>Please feel free to contact us.<\/strong><\/p>\n\n<p>If you want to verify 5G, customize a radio wave shield box, or need product repair, please do not hesitate to contact us about any small matter.<\/p>\n\n<div class=\"wp-block-vk-blocks-grid-column vk_gridColumn\"><div class=\"row\"><div class=\"wp-block-vk-blocks-grid-column-item vk_gridColumn_item col-12 col-sm-12 col-md-12 col-lg-12 col-xl-12 col-xxl-12\"><div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block is-style-shine\"><a href=\"https:\/\/micronix-jp.com\/english\/contact\/\" class=\"vk_button_link btn has-background has-luminous-vivid-orange-background-color btn-lg btn-block\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><i class=\"far fa-envelope vk_button_link_before\" aria-hidden=\"true\"><\/i><span class=\"vk_button_link_txt\"><strong>Contact Form<\/strong><\/span><\/div><\/a><\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Test systems for production, indispensable for OBE production lines and development fuses.<\/p>\n","protected":false},"featured_media":6069,"template":"","meta":{"vkexunit_cta_each_option":""},"product_cat":[91],"product_tag":[100],"class_list":{"0":"post-6039","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-shop-category-discontinued-product","7":"product_tag-tag-etc-inspection-system-for-obe-production","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/product\/6039","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media\/6069"}],"wp:attachment":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media?parent=6039"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/product_cat?post=6039"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/product_tag?post=6039"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}