{"id":5954,"date":"2007-12-18T12:09:26","date_gmt":"2007-12-18T03:09:26","guid":{"rendered":"https:\/\/micronix-jp.com\/english\/?post_type=product&#038;p=5954"},"modified":"2024-04-05T13:40:30","modified_gmt":"2024-04-05T04:40:30","slug":"line-impedance-stabilization-networklisn-mpw201b","status":"publish","type":"product","link":"https:\/\/micronix-jp.com\/english\/products\/emc\/mpw201b.html","title":{"rendered":"Line Impedance Stabilization Network(LISN) MPW201B"},"content":{"rendered":"<div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block\"><a href=\"\/eng\/file-download\/catalog\/MPW201B-EN.pdf\" class=\"vk_button_link btn has-background has-vk-color-primary-background-color btn-lg btn-block\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><i class=\"fas fa-file-pdf vk_button_link_before\" aria-hidden=\"true\"><\/i><span class=\"vk_button_link_txt\">Download catalog<\/span><\/div><\/a><\/div><div class=\"wp-block-vk-blocks-table-of-contents-new vk_tableOfContents vk_tableOfContents-style-default tabs\"><div class=\"tab\"><div class=\"vk_tableOfContents_title\">\u76ee\u6b21<\/div><input type=\"checkbox\" id=\"chck1\"\/><label class=\"tab-label vk_tableOfContents_openCloseBtn button_status button_status-close\" for=\"chck1\"><\/label><ul class=\"vk_tableOfContents_list tab_content-close\"><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-2\"><a href=\"#vk-htags-7e431671-7c33-438b-ba62-17f1171abf51\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">1. <\/span>EMI conducted emission measurement<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-2\"><a href=\"#vk-htags-751d46a5-e5bc-4b5d-8bf3-21bbb83e77f9\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">2. <\/span>Structure<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-3\"><a href=\"#vk-htags-0fe70f68-8552-4095-8799-27d7d2916028\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">2.1. <\/span>Confirmity to CISPR16-1<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-2\"><a href=\"#vk-htags-03ae29c8-0b3b-432a-806d-01a9f7cd0c36\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">3. <\/span>Specification<\/a><\/li><\/ul><\/div><\/div><h2 class=\"wp-block-heading\" id=\"vk-htags-7e431671-7c33-438b-ba62-17f1171abf51\">EMI conducted emission measurement<\/h2><p>When the conducted emission discharged through the power supply line is measured, the measured value is influenced from the impedance of the power source.<\/p><p>The noise level is measured low if the impedance is low, and it is measured high if oppositely high. With this, there are neither universality nor reliability in the measured value.<\/p><p>Then, to measure the disturbance noise with stability and reproducibility, the impedance of the power source should be made constant. The impedance of the power source observed from EUT side is made constant by inserting the line impedance stabilization network (LISN) in the power supply line.<\/p><p>However, the impedance of power supply line has the frequency characteristics but the impedance curve is provided by CISPR.<\/p><h2 class=\"wp-block-heading\" id=\"vk-htags-751d46a5-e5bc-4b5d-8bf3-21bbb83e77f9\">Structure<\/h2><figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"680\" height=\"376\" src=\"https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/mpw201b-00.gif\" alt=\"\" class=\"wp-image-8678\"\/><\/figure><h3 class=\"vk_block-margin-md--margin-top wp-block-heading\" id=\"vk-htags-0fe70f68-8552-4095-8799-27d7d2916028\">Confirmity to CISPR16-1<\/h3><p>The circuit of MPW201B adopts &lt;50\u03a9\/50\u03bcH and V type&gt; based on CISPR16-1.<\/p><p>The frequency range is from 150kHz to 30MHz, and the conditions of power supply are single phase, maximum voltage 250VAC, rated current 15A and 50\/60Hz. As shown in the equivalent circuit, the disturbance noise discharged from EUT is led to a transient limiter with 50\u03a9 input through a high pass filter of a capacitor and resistors, and then input to Spectrum analyzer MSA438E\/538E\/558E.<\/p><p>The disturbance noise can be measured at both terminals of L1 and N, but a high voltage transient pulse may be generated when switching the measurement line. To protect the spectrum analyzer from this pulse, a transient limiter composed of 10dB attenuator and diodes is built in.<\/p><h2 class=\"wp-block-heading\" id=\"vk-htags-03ae29c8-0b3b-432a-806d-01a9f7cd0c36\">Specification<\/h2><figure class=\"wp-block-flexible-table-block-table\"><table class=\"\"><tbody><tr><th style=\"width:25%\">Frequency range<\/th><td>150kHz to 30MHz<\/td><\/tr><tr><th style=\"width:25%\">Circuit type<\/th><td>50\u03a9\/50\u03bcH and V type based on CISPR16-1<\/td><\/tr><tr><th style=\"width:25%\">Impedance accuracy<\/th><td>\u00b120\uff05<\/td><\/tr><tr><th style=\"width:25%\">Number of phase<\/th><td>Single<\/td><\/tr><tr><th style=\"width:25%\">Max. power supply voltage<\/th><td>250VAC<\/td><\/tr><tr><th style=\"width:25%\">Rated current<\/th><td>15A<\/td><\/tr><tr><th style=\"width:25%\">Power supply frequency<\/th><td>50\/60Hz<\/td><\/tr><tr><th style=\"width:25%\">RF Connectors<\/th><td>BNC female<\/td><\/tr><tr><th style=\"width:25%\">Transient limiter<\/th><td>Built-in<\/td><\/tr><tr><th style=\"width:25%\">Operating temperature<\/th><td>0 to 40\u2103(Guaranteed at 23\u00b110\u2103)<\/td><\/tr><tr><th style=\"width:25%\">Dimensions<\/th><td>260(W)\u00d7125(H)\u00d7220(D)mm \uff08excluding projections\uff09<\/td><\/tr><tr><th style=\"width:25%\">Weight<\/th><td>approx. 2.3kg<\/td><\/tr><\/tbody><\/table><\/figure><p>The leakage current due to the capacitor built into the LISN (MPW201B) is approximately 53 mA @ 100 VAC\/50 Hz, which may cause an electric shock or trip the breaker of the power supply. It is recommended that an isolation transformer or AC stabilized power supply be provided separately from this product and installed between LISN (MPW201B) and the AC power line.<\/p><div class=\"wp-block-cover is-light vk_block-margin-xl--margin-top\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-white-background-color has-background-dim\"><\/span><img class=\"wp-block-cover__image-background wp-image-8105\" alt=\"\" src=\"https:\/\/micronix-jp.com\/wp-content\/uploads\/2022\/11\/contact_cta_cover.png\" data-object-fit=\"cover\"\/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><p class=\"has-text-align-center has-huge-font-size\"><strong>Please feel free to contact us.<\/strong><\/p>\n\n<p>If you want to verify 5G, customize a radio wave shield box, or need product repair, please do not hesitate to contact us about any small matter.<\/p>\n\n<div class=\"wp-block-vk-blocks-grid-column vk_gridColumn\"><div class=\"row\"><div class=\"wp-block-vk-blocks-grid-column-item vk_gridColumn_item col-12 col-sm-12 col-md-12 col-lg-12 col-xl-12 col-xxl-12\"><div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block is-style-shine\"><a href=\"https:\/\/micronix-jp.com\/english\/contact\/\" class=\"vk_button_link btn has-background has-luminous-vivid-orange-background-color btn-lg btn-block\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><i class=\"far fa-envelope vk_button_link_before\" aria-hidden=\"true\"><\/i><span class=\"vk_button_link_txt\"><strong>Contact Form<\/strong><\/span><\/div><\/a><\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>A test environment can be easily constructed in a limited space.<br \/>\nLISN is necessary to perform stably and reproducible disturbance noise measurement.<br \/>\nThe impedance of the power source observed from EUT side is made constant by inserting LISN in the power supply line.<\/p>\n","protected":false},"featured_media":5997,"template":"","meta":{"vkexunit_cta_each_option":""},"product_cat":[97],"product_tag":[98,99],"class_list":{"0":"post-5954","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-shop-category-emc-test-system","7":"product_tag-tag-emi-test-system","8":"product_tag-tag-ems-test-system","10":"first","11":"instock","12":"shipping-taxable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/product\/5954","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media\/5997"}],"wp:attachment":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media?parent=5954"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/product_cat?post=5954"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/product_tag?post=5954"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}