{"id":5395,"date":"2022-06-14T16:46:59","date_gmt":"2022-06-14T07:46:59","guid":{"rendered":"https:\/\/micronix-jp.com\/english\/?p=5395"},"modified":"2023-03-25T10:46:00","modified_gmt":"2023-03-25T01:46:00","slug":"for-spectrum-analyzer-logging-softwareintroduction-of-mas410%e3%83%bb510","status":"publish","type":"post","link":"https:\/\/micronix-jp.com\/english\/tech\/technology\/introduction_of_logging_soft.html","title":{"rendered":"For spectrum analyzer Logging software Introduction of MAS410\u30fb510"},"content":{"rendered":"<section>\n<h2>Introduction<\/h2>\n<p>PC software for controlling spectrum analyzers (MSA400 series) and signal spectrum analyzers (MSA500 series) and logging measurement data. It is ideal for monitoring abnormal signals, interference, and interfering radio waves during the day and night, and for recording unmanned data for a long time. <\/p>\n\n<h2>System image<\/h2>\n\n<img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/technology\/mas_logging-00.png\" alt=\"\u30b7\u30b9\u30c6\u30e0\u30a4\u30e1\u30fc\u30b8\" width=\"730\" height=\"336\">\n\n<h2>Operating environment<\/h2>\n<ul>\n  <li>Recommended PC\uff1aCPU 2GHz or more, memory 2GB or more, HDD free space 1GB or more <\/li>\n<li>Compatible OS\uff1aWindows 7 \/ 8 \/ 10 \u3000\u3000\u203b32 \/ 64bit compatible<\/li>\n<li>Interface\uff1aUSB 2 ports or more<\/li>\n<\/ul>\n\n<h2>Software overview<\/h2>\n<p>It consists of two screens, recording mode and playback mode.\n<br>\nOnly PCs with a USB dongle key can be transferred to the recording mode (1 license per spectrum analyzer). <\/p>\n\n<ul class=\"flexBox flexBoxDivide\">\n  <li class=\"textCenter\" style=\"margin-bottom:2em\">\n  <p style=\"margin-bottom:0\">Recording mode (setting screen) <\/p>\n  <img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/technology\/mas_logging-01.png\" alt=\"\u8a18\u9332\u30e2\u30fc\u30c9\uff08\u8a2d\u5b9a\u753b\u9762\uff09\" width=\"293\" height=\"271\">\n  <\/li>\n  <li class=\"textCenter\" style=\"margin-bottom:2em\">\n  <p style=\"margin-bottom:0\">Playback mode (when 4 screens are displayed) <\/p>\n  <img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/technology\/mas_logging-02.png\" alt=\"\u518d\u751f\u30e2\u30fc\u30c9\uff084\u753b\u9762\u8868\u793a\u6642\uff09\" width=\"293\" height=\"272\">\n  <\/li>\n<\/ul>\n\n\n<h2>Software specifications (recording mode)<\/h2>\n\n<img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/technology\/mas_logging-03.png\" alt=\"\u8868\u793a\u753b\u9762\u8aac\u660e\uff1a\u8a18\u9332\u30e2\u30fc\u30c9\" width=\"730\" height=\"438\">\n\n<h2>Software specifications (playback mode)<\/h2>\n\n<img decoding=\"async\" src=\"\/eng\/image\/technology\/mas_logging-04.png\" alt=\"\u8868\u793a\u753b\u9762\u8aac\u660e\uff1a\u518d\u751f\u30e2\u30fc\u30c9\" width=\"809\" style=\"margin-bottom:4em\">\n\n<img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/technology\/mas_logging-05.png\" alt=\"\u8868\u793a\u753b\u9762\u8aac\u660e\uff1a\u518d\u751f\u30e2\u30fc\u30c9\" width=\"730\" height=\"384\">\n\n<h2>Estimated recording capacity<\/h2>\n<p>The approximate recording capacity for the recording time (period) is as follows.<\/p>\n\n\n<style>\n.table-scroll { \n  overflow: auto;\n  }\n  \ntable.Nowrap th,\ntable.Nowrap td{\n  white-space:nowrap;\n}\n<\/style>\n\n<table class=\"type01 thCenter\" style=\"width:auto\">\n  <tbody><tr>\n    <th>1 minute <\/th>\n    <th>1 hour <\/th>\n    <th>1 day <\/th>\n    <th>1 week <\/th>\n  <\/tr>\n  <tr>\n    <td>60frame<\/td>\n    <td>3,600frame<\/td>\n    <td>86,400frame<\/td>\n    <td>604,800frame<\/td>\n  <\/tr>\n  <tr>\n    <td>About 70KB <\/td>\n    <td>About 4.2MB <\/td>\n    <td>About 100MB <\/td>\n    <td>About 700MB <\/td>\n  <\/tr>\n<\/tbody><\/table>\n\n\n<p style=\"margin-top:0\">\u203b Measurement interval: 1 second<\/p>\n\n<h2>Supplementary information \u30fb Precautions for handling<\/h2>\n<ul>\n  <li>If your PC has multiple SIO ports, you can control multiple analyzers by launching this software for multiple tasks and allocating the ports. <\/li>\n  <li>When operating this software continuously, the operation will stop if the logout function of the screen saver is ON. If you want to operate for a long time, turn off the logout function. <\/li>\n  <li>If the virus check software is running or resident, a communication error may occur. In such a case, stop the virus check function.<\/li>\n<\/ul>\n<\/section>\n  \n<section>\n<h2>Log file converter\u3000MAS410CONV\u30fb510CONV<\/h2>\n<h3>1.Introduction<\/h3>\n<p>Log file converter is PC software that converts log data collected by MAS410 or MAS510 logging software into CSV files. Specifies the range of frames recorded in the log file that are output to the CSV file. Slide the trackbar of each start frame and end frame left or right or specify the frame number in the edit box. If not changed, all frames will be output. <\/p>\n\n  <img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/technology\/mas_logging-06.png\" alt=\"\u30ed\u30b0\u30d5\u30a1\u30a4\u30eb\u30b3\u30f3\u30d0\u30fc\u30bf\u3000MAS510CONV\" width=\"930\" height=\"322\">\n  \n<h3>2.Extracted CSV data<\/h3>  \n  <p>CSV data consists of a measurement condition part and a waveform data part. \n<\/p>\n \n\n  <p>\n  \n<img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/technology\/mas_logging-07.png\" alt=\"CSV\u30c7\u30fc\u30bf\" width=\"930\" height=\"433\"><\/p>\n<\/section>  \n  \n  \n<section>\n<h2>Products introduction<\/h2>\n\n<div class=\"woocommerce \"><\/div>\n<\/section><div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block\"><a href=\"\/eng\/file-download\/technical\/pdf\/Introduction_of_Logging_Soft.pdf\" style=\"background-color:#726756;border:1px solid #726756;color:#fff;\" class=\"vk_button_link btn btn-md btn-block white\" role=\"button\" aria-pressed=\"true\" target=\"_blank\"  rel=\"noopener\"><i class=\"fas vk_button_link_before fa-file-pdf\"><\/i><span class=\"vk_button_link_txt\">Download This Technical Report (PDF) <\/span><\/a><\/div><p><\/p><div class=\"wp-block-cover is-light vk_block-margin-xl--margin-top\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-white-background-color has-background-dim\"><\/span><img class=\"wp-block-cover__image-background wp-image-8105\" alt=\"\" src=\"https:\/\/micronix-jp.com\/wp-content\/uploads\/2022\/11\/contact_cta_cover.png\" data-object-fit=\"cover\"\/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><p class=\"has-text-align-center has-huge-font-size\"><strong>Please feel free to contact us.<\/strong><\/p>\n\n<p>If you want to verify 5G, customize a radio wave shield box, or need product repair, please do not hesitate to contact us about any small matter.<\/p>\n\n<div class=\"wp-block-vk-blocks-grid-column vk_gridColumn\"><div class=\"row\"><div class=\"wp-block-vk-blocks-grid-column-item vk_gridColumn_item col-12 col-sm-12 col-md-12 col-lg-12 col-xl-12 col-xxl-12\"><div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block is-style-shine\"><a href=\"https:\/\/micronix-jp.com\/english\/contact\/\" class=\"vk_button_link btn has-background has-luminous-vivid-orange-background-color btn-lg btn-block\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><i class=\"far fa-envelope vk_button_link_before\" aria-hidden=\"true\"><\/i><span class=\"vk_button_link_txt\"><strong>Contact Form<\/strong><\/span><\/div><\/a><\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction PC software for controlling spectrum analyzers (MSA400 series) and signal spectrum analyzers (MSA500 series) and logging measurement data. It is ideal for monitoring abnormal signals, interference, and interfering radio [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":8285,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"vkexunit_cta_each_option":"","footnotes":""},"categories":[32],"tags":[86],"class_list":["post-5395","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-category-technology","tag-technology-spectrum-analyzer"],"_links":{"self":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/5395","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/comments?post=5395"}],"version-history":[{"count":1,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/5395\/revisions"}],"predecessor-version":[{"id":6975,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/5395\/revisions\/6975"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media\/8285"}],"wp:attachment":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media?parent=5395"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/categories?post=5395"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/tags?post=5395"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}