{"id":2281,"date":"2015-06-01T00:00:54","date_gmt":"2015-05-31T15:00:54","guid":{"rendered":"https:\/\/micronix-jp.com\/?p=2281"},"modified":"2023-03-20T17:18:55","modified_gmt":"2023-03-20T08:18:55","slug":"ems_probe","status":"publish","type":"post","link":"https:\/\/micronix-jp.com\/english\/note\/application\/ems_probe.html","title":{"rendered":"Measures against radiated immunity test using electric field probe"},"content":{"rendered":"<p class=\"bigTitle\" style=\"margin-bottom: 1em\"> Pre-compliance EMS(immunity) testing<\/p>\n\n\n<h2>Application<\/h2>\n<p>Instead of carrying an equipment to be measured (EUT) to the EMC test site and accomplishing the immunity test many times, it is possible to perform a disturbance wave test easily. <\/p>\n<p>Operate a dedicated program and measure the electric field strength of disturbance radio waves. <\/p>\n<p>Follow the on - screen instructions on the GUI and measure the target area (max. 4) with the electric field probe.<\/p>\n<p>The calibration data with high degree of freedom is automatically created while changing the position of the probe  in order to improve the test accuracy.<\/p>\n\n\n\n<h2>Solution<\/h2>\n<p>Install an electric field probe on the EUT installation stage in the anechoic box.  The calibration data is automatically created by the test software according to the size of EUT.<\/p>\n<ol>\n<li>Install an electric field probe at an arbitrary position on the stage.<\/li>\n<li>Align it on the EUT face facing the antenna, and measure the electric field  strength (max. 4 places).<\/li>\n<li>Record the calibration data of each position according to the target frequency  range.<\/li>\n<li>Install the calibration data in test software and start EMS precompliance test.<\/li>\n<\/ol>\n<img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/application\/ems_probe-00.gif\" alt=\"Pre-compliance EMS(immunity) testing\" width=\"900\" height=\"589\"> \n\n\n<h2>System configuration<\/h2>\n<table width=\"900\">\n<tbody><tr>\n<th width=\"50\" nowrap=\"\">[Basic configuration]<\/th>\n<\/tr>\n<tr>\n<td><a href=\"\/english\/products\/shield-box\/\">Electromagnetic anechoic box<\/a><\/td>\n<\/tr>\n<tr>\n<td>Log PeriodicAntenna <\/td>\n<\/tr>\n<tr>\n<td>Electric field probe<\/td>\n<\/tr>\n<tr>\n<td>Power Amplifier ( until 1GHz )<\/td>\n<\/tr>\n<tr>\n<td>Signal generator ( until 1GHz )<\/td>\n<\/tr>\n<tr>\n<td>PC \/ Immunity test software<\/td>\n<\/tr>\n<tr>\n<th>[OPTION]<\/th>\n<\/tr>\n<tr>\n<td><a href=\"\/english\/products\/emc\/mr2350.html\">EUT camera monitor<\/a><\/td>\n<\/tr>\n<tr>\n<td>Log PeriodicAntenna <\/td>\n<\/tr>\n<tr>\n<td>Power Amplifier ( more than 1GHz  *negotiable)<\/td>\n<\/tr>\n<tr>\n<td>Signal generator (  more than 1GHz  *negotiable)<\/td>\n<\/tr>\n<tr>\n<td>RF Selector<\/td>\n<\/tr>\n<tr>\n<td>Interlock mechanism<\/td>\n<\/tr>\n<\/tbody><tfoot>\n<\/tfoot>\n<\/table>\n\n\n\n<h2>Products introduction<\/h2>\n <div class=\"woocommerce columns-3 \"><ul class=\"products columns-3\">\n<li class=\"product type-product post-6063 status-publish first instock product_cat-shop-category-emc-test-system product_tag-tag-emi-test-system product_tag-tag-ems-test-system has-post-thumbnail shipping-taxable product-type-simple\">\n\t<a href=\"https:\/\/micronix-jp.com\/english\/products\/emc\/mec235\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/MEC235_640x640-300x300.png\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"\" srcset=\"https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/MEC235_640x640-300x300.png 300w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/MEC235_640x640-150x150.png 150w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/MEC235_640x640-100x100.png 100w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/MEC235_640x640.png 620w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><h2 class=\"woocommerce-loop-product__title\">EUT camera monitor MEC235<\/h2>\n<\/a><\/li>\n<\/ul>\n<\/div><div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block\"><a href=\"\/eng\/file-download\/application\/pdf\/ems_probe_e.pdf\" style=\"background-color:#5b6069;border:1px solid #5b6069;color:#fff;\" class=\"vk_button_link btn btn-md btn-block white\" role=\"button\" aria-pressed=\"true\" target=\"_blank\"  rel=\"noopener\"><i class=\"fas vk_button_link_before fa-file-pdf\"><\/i><span class=\"vk_button_link_txt\">Download This Application Note (PDF) <\/span><\/a><\/div><p><\/p><div class=\"wp-block-cover is-light vk_block-margin-xl--margin-top\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-white-background-color has-background-dim\"><\/span><img class=\"wp-block-cover__image-background wp-image-8105\" alt=\"\" src=\"https:\/\/micronix-jp.com\/wp-content\/uploads\/2022\/11\/contact_cta_cover.png\" data-object-fit=\"cover\"\/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><p class=\"has-text-align-center has-huge-font-size\"><strong>Please feel free to contact us.<\/strong><\/p>\n\n<p>If you want to verify 5G, customize a radio wave shield box, or need product repair, please do not hesitate to contact us about any small matter.<\/p>\n\n<div class=\"wp-block-vk-blocks-grid-column vk_gridColumn\"><div class=\"row\"><div class=\"wp-block-vk-blocks-grid-column-item vk_gridColumn_item col-12 col-sm-12 col-md-12 col-lg-12 col-xl-12 col-xxl-12\"><div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block is-style-shine\"><a href=\"https:\/\/micronix-jp.com\/english\/contact\/\" class=\"vk_button_link btn has-background has-luminous-vivid-orange-background-color btn-lg btn-block\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><i class=\"far fa-envelope vk_button_link_before\" aria-hidden=\"true\"><\/i><span class=\"vk_button_link_txt\"><strong>Contact Form<\/strong><\/span><\/div><\/a><\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Pre-compliance EMS(immunity) testing Application Instead of carrying an equipment to be measured (EUT) to the EMC test site and accomplishing the immunity test many times, it is possible to perform [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":8216,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"sns_share_botton_hide":"","vkExUnit_sns_title":"","_vk_print_noindex":"","sitemap_hide":"","_veu_custom_css":"<!--\u8a18\u4e8b\u306e\u30a2\u30a4\u30ad\u30e3\u30c3\u30c1\u3092\u6d88\u3059-->\n.veu_autoEyeCatchBox{\ndisplay:none;\n}","veu_display_promotion_alert":"","vkexunit_cta_each_option":"","_lightning_design_setting":{"layout":"default"},"header_top_description":"","footnotes":""},"categories":[17],"tags":[44,66,71,73],"class_list":["post-2281","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-category-note","tag-app-emc","tag-market-emc","tag-application-emc","tag-application-shield-box"],"veu_head_title_object":{"title":"","add_site_title":""},"_links":{"self":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/2281","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/comments?post=2281"}],"version-history":[{"count":1,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/2281\/revisions"}],"predecessor-version":[{"id":7033,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/2281\/revisions\/7033"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media\/8216"}],"wp:attachment":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media?parent=2281"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/categories?post=2281"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/tags?post=2281"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}