{"id":2272,"date":"2010-07-01T00:00:54","date_gmt":"2010-06-30T15:00:54","guid":{"rendered":"https:\/\/micronix-jp.com\/?p=2272"},"modified":"2023-03-20T17:27:32","modified_gmt":"2023-03-20T08:27:32","slug":"zyouhou","status":"publish","type":"post","link":"https:\/\/micronix-jp.com\/english\/note\/application\/zyouhou.html","title":{"rendered":"Noise immunity evaluation of information and communication equipment"},"content":{"rendered":"<p class=\"bigTitle\" style=\"margin-bottom: 1em\"> The correlation between noise level and transmission speed are verified.<\/p>\n\n\n<h2>Application<\/h2>\n<p>In this paper, the evaluation of a mobile phone module is mentioned as an example. <\/p>\n<p>This system intends to evaluate how the EUT (mobile phone module) put in anechoic box is affected after the signal output from signal generator (SG) is radiated in it.   This system has the frequency range from 800MHz to 2.5GHz and is a tool for detecting the EMC problem in the early stage of design or measuring a communication effective throughput by the program of EUT or control equipment.<\/p>\n\n\n\n<h2>Solution<\/h2>\n<h3>System configuration example<\/h3>\n<div class=\"inline\">\n<ol>\n<li>Transmission section (1)(2)<\/li>\n<li>Evaluation stage<\/li>\n<li>Measurement &amp; display section<\/li>\n<\/ol>\n<\/div>\n<img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/application\/zyouhou-00.gif\" alt=\"Figure:System configuration example\" width=\"730\" height=\"221\" style=\"margin-bottom:2em\">\n\n<h2>System specification example<\/h2>\n\n<ol>\n<li>Transmission section *Insert an isolator if necessary.\n<p style=\"padding-left:1em\"> The signal to be applied to EUT is generated.  The power is roughly +30 dBm but depending on the measurement band. Transmission section (1) and (2) are installed in one case.<\/p>\n<table>\n<tbody><tr>\n<td rowspan=\"2\">Signal generator<\/td>\n<td>Frequency range<\/td>\n<td>9kHz to 3GHz(CW)<\/td>\n<\/tr>\n<tr>\n<td>Output level<\/td>\n<td>-127 to \uff0b13dBm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" nowrap=\"\">Power amplifier<\/td>\n<td>Frequency range<\/td>\n<td>800MHz to 2.5GHz<\/td>\n<\/tr>\n<tr>\n<td>Output power<\/td>\n<td>5W\u4ee5\u4e0a<\/td>\n<\/tr>\n<tr>\n<td>LPF*<\/td>\n<td colspan=\"2\">Cutoff frequency is 1GHz at the measurement from 800MHz to 1GHz, and  2GHz at the measurement from 1.5GHz to 2GHz.<\/td>\n<\/tr>\n<tr>\n<td>HPF*<\/td>\n<td colspan=\"2\">Cutoff frequency is 1.6GHz at the measurement from 800MHz to 1GHz, and  3GHz at the measurement from 1.5GHz to 2GHz.<\/td>\n<\/tr>\n<tr>\n<td>DC block<\/td>\n<td colspan=\"2\">Parts for cutting DC<\/td>\n<\/tr>\n<\/tbody><\/table>\n<p class=\"clear\"><\/p>\n<\/li>\n<li>Evaluation stage\n<p style=\"padding-left:1em\"> The signal generated at \u2460 is radiated in anechoic box through an antenna coupler. <\/p>\n<table>\n<tbody><tr>\n<td rowspan=\"5\">Anechoic box<\/td>\n<td>Shielding effectiveness<\/td>\n<td>800MHz to 3GHz(more than 50dB)<\/td>\n<\/tr>\n<tr>\n<td>Outside dimensions<\/td>\n<td>approx. 260(W) x 260(H) x 360(D)mm<\/td>\n<\/tr>\n<tr>\n<td>Inside dimensions<\/td>\n<td>approx. 200(W) x 100(H) x 300(D)mm<\/td>\n<\/tr>\n<tr>\n<td>Table for put EUT<\/td>\n<td>200(W) x 280(D)mm<\/td>\n<\/tr>\n<tr>\n<td>I\/F<\/td>\n<td>SMA connector *2pcs<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Antenna coupler<\/td>\n<td>Frequency range<\/td>\n<td>800MHz to 2.5GHz<\/td>\n<\/tr>\n<tr>\n<td>VSWR<\/td>\n<td>2.5\u4ee5\u4e0b(800MHz to 2.2GHz)<\/td>\n<\/tr>\n<tr>\n<td>Maximum output level<\/td>\n<td>\uff0b38dBm<\/td>\n<\/tr>\n<\/tbody><\/table>\n<p class=\"clear\"><\/p>\n<\/li>\n<li>Measurement &amp; display section\n<p style=\"padding-left:1em\"> The report will be drawn up after measured in the circumstance of \u2461.<\/p>\n<table>\n<tbody><tr>\n<td>Spectrum Analyzer<\/td>\n<td>Frequency range<\/td>\n<td>50kHz to 8.5GHz<\/td>\n<\/tr>\n<tr>\n<td>PC software<\/td>\n<td colspan=\"2\">The result obtained by spectrum analyzer is displayed and the report  is drawn up. <\/td>\n<\/tr>\n<tr>\n<td>PC<\/td>\n<td colspan=\"2\">The communication status such as the effective throughput is made sure using the program of control equipment and EUT.<\/td>\n<\/tr>\n<\/tbody><\/table>\n<p class=\"clear\"><\/p>\n<\/li>\n<\/ol>\n\n\n\n<h2>Products introduction<\/h2>\n<div class=\"woocommerce columns-3 \"><ul class=\"products columns-3\">\n<li class=\"product type-product post-5788 status-publish first instock product_cat-shop-category-handheld-spectrum-analyzer product_cat-shop-category-msa400 product_tag-tag-handheld-spectrum-analyzer has-post-thumbnail shipping-taxable product-type-simple\">\n\t<a href=\"https:\/\/micronix-jp.com\/english\/products\/spectrum-analyzer\/msa400\/msa458.html\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/msa458_620x620-300x300.png\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"\" srcset=\"https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/msa458_620x620-300x300.png 300w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/msa458_620x620-150x150.png 150w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/msa458_620x620-600x600.png 600w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/msa458_620x620-100x100.png 100w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/msa458_620x620.png 620w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><h2 class=\"woocommerce-loop-product__title\">Handheld Spectrum Analyzer MSA458<\/h2>\n<\/a><\/li>\n<\/ul>\n<\/div><div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block\"><a href=\"\/eng\/file-download\/application\/pdf\/noise_immunity.pdf\" style=\"background-color:#5b6069;border:1px solid #5b6069;color:#fff;\" class=\"vk_button_link btn btn-md btn-block white\" role=\"button\" aria-pressed=\"true\" target=\"_blank\"  rel=\"noopener\"><i class=\"fas vk_button_link_before fa-file-pdf\"><\/i><span class=\"vk_button_link_txt\">Download This Application Note (PDF) <\/span><\/a><\/div><p><\/p><div class=\"wp-block-cover is-light vk_block-margin-xl--margin-top\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-white-background-color has-background-dim\"><\/span><img class=\"wp-block-cover__image-background wp-image-8105\" alt=\"\" src=\"https:\/\/micronix-jp.com\/wp-content\/uploads\/2022\/11\/contact_cta_cover.png\" data-object-fit=\"cover\"\/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><p class=\"has-text-align-center has-huge-font-size\"><strong>Please feel free to contact us.<\/strong><\/p>\n\n<p>If you want to verify 5G, customize a radio wave shield box, or need product repair, please do not hesitate to contact us about any small matter.<\/p>\n\n<div class=\"wp-block-vk-blocks-grid-column vk_gridColumn\"><div class=\"row\"><div class=\"wp-block-vk-blocks-grid-column-item vk_gridColumn_item col-12 col-sm-12 col-md-12 col-lg-12 col-xl-12 col-xxl-12\"><div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block is-style-shine\"><a href=\"https:\/\/micronix-jp.com\/english\/contact\/\" class=\"vk_button_link btn has-background has-luminous-vivid-orange-background-color btn-lg btn-block\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><i class=\"far fa-envelope vk_button_link_before\" aria-hidden=\"true\"><\/i><span class=\"vk_button_link_txt\"><strong>Contact Form<\/strong><\/span><\/div><\/a><\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>The correlation between noise level and transmission speed are verified. Application In this paper, the evaluation of a mobile phone module is mentioned as an example. This system intends to [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":8210,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"vkexunit_cta_each_option":"","footnotes":""},"categories":[17],"tags":[36,46,68,73,74,75],"class_list":["post-2272","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-category-note","tag-app-4g-5g","tag-app-interfering-wave","tag-market-wireless-communication","tag-application-shield-box","tag-application-signal-generator","tag-application-spectrum-analyzer"],"_links":{"self":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/2272","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/comments?post=2272"}],"version-history":[{"count":1,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/2272\/revisions"}],"predecessor-version":[{"id":7083,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/2272\/revisions\/7083"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media\/8210"}],"wp:attachment":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media?parent=2272"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/categories?post=2272"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/tags?post=2272"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}