{"id":2266,"date":"2010-02-01T00:00:54","date_gmt":"2010-01-31T15:00:54","guid":{"rendered":"https:\/\/micronix-jp.com\/?p=2266"},"modified":"2023-03-20T17:28:09","modified_gmt":"2023-03-20T08:28:09","slug":"mp300-sol","status":"publish","type":"post","link":"https:\/\/micronix-jp.com\/english\/note\/application\/mp300-sol.html","title":{"rendered":"Tool for analysis of high frequency circuit design"},"content":{"rendered":"<p class=\"bigTitle\" style=\"margin-bottom: 1em\">Optium tool for analysis of high-frequency circuit design \uff08High-frequency passive probe MP300\uff09\n\n<\/p>\n<h2>Application<\/h2>\n<p> MP300 is a passive probe that has a wide frequency range and low input capacitance. It is used in connected with measurment equipment (Spectrum analyzer or Oscilloscope).  Danping ratio is 10:1 for that MP300's input resistance is 500\u03a9. Its ratio is quite lower than popular passive probe and FET probe. <\/p>\n<p>Operator is demanded a little attention when measure the circuit in low frequency range (DC-XXKHz) However,since this probe is low input capacitance and low impedance, it has favourable frequency response in high frequency range. It is useful for analysis and diagnostics on high-frequency circuit design.<\/p>\n\n\n\n<h2>Solution<\/h2>\n\n<h3>Configuration<\/h3>\n<img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/application\/MP300-sol-00.jpg\" alt=\"Figure:Configuration\" width=\"450\" height=\"281\">\n\n<h3>Performance table<\/h3>\n<table>\n<tbody><tr>\n<th class=\"Center\">Item<\/th>\n<th class=\"Center\">Specification<\/th>\n<\/tr>\n<tr>\n<td>frequency bandwidth\uff08-3dB\uff09<\/td>\n<td>6GHz<\/td>\n<\/tr>\n<tr>\n<td>attenaution ratio<\/td>\n<td>10:1\u00b12%<br>\n(50\u03a9\u00b11% connected load)<\/td>\n<\/tr>\n<tr>\n<td>input resistance<\/td>\n<td>500\u03a9\u00b12%<br>\n(50\u03a9\u00b11% connected load)<\/td>\n<\/tr>\n<tr>\n<td>input capability<\/td>\n<td>0.25pF(typ)<\/td>\n<\/tr>\n<tr>\n<td>cable length<\/td>\n<td>1m<\/td>\n<\/tr>\n<tr>\n<td>connector shape<\/td>\n<td>SMA<\/td>\n<\/tr>\n<tr>\n<td>input voltage endurance<\/td>\n<td>10Vrms, 20Vpeak(PW&lt;1ms)<\/td>\n<\/tr>\n<tr>\n<td>operating temperature range<\/td>\n<td>5 to 35\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>operating humidity range<\/td>\n<td>Less than 85%RH<br>\n(non condensing)<\/td>\n<\/tr>\n<tr>\n<td>storage temerature range<\/td>\n<td>-20 to 70\u00b0C<\/td>\n<\/tr>\n<\/tbody><\/table>\n\n\n\n\n<h3>Probe comparison table<\/h3>\n\n<table>\n<tbody><tr>\n<th rowspan=\"2\" nowrap=\"\" class=\"Center\">Probe<\/th>\n<th colspan=\"2\" nowrap=\"\" class=\"Center\">input impedance<\/th>\n<th rowspan=\"2\" nowrap=\"\" class=\"Center\">output impedance<\/th>\n<th rowspan=\"2\" nowrap=\"\" class=\"Center\">measurement Frequency range<br>\n(roughly)<\/th>\n<th rowspan=\"2\">Recital<\/th>\n<\/tr>\n<tr>\n<th>R<\/th>\n<th>C<\/th>\n<\/tr>\n<tr>\n<td>Oscillo \nprobe<br>\n(10:1)<\/td>\n<td>10M\u03a9<\/td>\n<td>10pF<\/td>\n<td>9M\u03a9<\/td>\n<td>DC to 200MHz<\/td>\n<td>Adjusting phase of the probe is required<\/td>\n<\/tr>\n<tr>\n<td>FET \nProbe<\/td>\n<td>100K\u03a9<\/td>\n<td>1 to 4pF<\/td>\n<td>50\u03a9<\/td>\n<td>DC to 1000MHz<\/td>\n<td>DC power supply is required<\/td>\n<\/tr>\n<tr>\n<td>MP300<\/td>\n<td>500\u03a9<\/td>\n<td>0.25pF<\/td>\n<td>50\u03a9<\/td>\n<td>DC to 6GHz<\/td>\n<td>input impedance is a little lower<\/td>\n<\/tr>\n<\/tbody><\/table>\n\n\n<h3>Fig of simple circuit component<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/application\/MP300-sol-01.gif\" alt=\"Figure:Fig of simple circuit component\" width=\"500\" height=\"151\"><\/p>\n\n<p style=\"border:#F00 solid 2px;padding:.5rem\">Suit for comparison of simulation\nresults and failure analysis on\ndesign of high-frequency. <\/p>\n<p>*Indicate is 20dB lower than a given level by using  50\u03a9 line measuring equipment for that probe input impedance is 500\u03a9.<br>\n*20 log 50 \/ 500<\/p>\n\n\n<p>If this circuit is inputted 0dBm.Since there are three 10dBm amplifers on it, Implicit output level is +30dBm. When 50 \u03a9  lines Measuring equipment doesn't indicate +10 dBm on output point. ,there is a defect on this cirucuit. Measuring each point (P1,P2,P3,P4,) by using this probe that can caluculate where circuit defect arise.<\/p>\n\n\n\n<h2>Products introduction<\/h2>\n<div class=\"woocommerce \"><ul class=\"products columns-4\">\n<li class=\"product type-product post-5805 status-publish first instock product_cat-shop-category-handheld-spectrum-analyzer product_cat-shop-category-spectrum-analyzer-option product_cat-shop-category-test-accessories product_tag-tag-handheld-spectrum-analyzer-option product_tag-tag-test-accessories has-post-thumbnail shipping-taxable product-type-simple\">\n\t<a href=\"https:\/\/micronix-jp.com\/english\/products\/test-accessories\/mp300.html\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/MP300_620x620-300x300.png\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"\" srcset=\"https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/MP300_620x620-300x300.png 300w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/MP300_620x620-150x150.png 150w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/MP300_620x620-600x600.png 600w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/MP300_620x620-100x100.png 100w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/MP300_620x620.png 620w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><h2 class=\"woocommerce-loop-product__title\">[Discontinued product] Wide Band Passive Probe MP300<\/h2>\n<\/a><\/li>\n<\/ul>\n<\/div><div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block\"><a href=\"\/eng\/file-download\/application\/pdf\/MP300_tool.pdf\" style=\"background-color:#5b6069;border:1px solid #5b6069;color:#fff;\" class=\"vk_button_link btn btn-md btn-block white\" role=\"button\" aria-pressed=\"true\" target=\"_blank\"  rel=\"noopener\"><i class=\"fas vk_button_link_before fa-file-pdf\"><\/i><span class=\"vk_button_link_txt\">Download This Application Note (PDF) <\/span><\/a><\/div><p><\/p><div class=\"wp-block-cover is-light vk_block-margin-xl--margin-top\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-white-background-color has-background-dim\"><\/span><img class=\"wp-block-cover__image-background wp-image-8105\" alt=\"\" src=\"https:\/\/micronix-jp.com\/wp-content\/uploads\/2022\/11\/contact_cta_cover.png\" data-object-fit=\"cover\"\/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><p class=\"has-text-align-center has-huge-font-size\"><strong>Please feel free to contact us.<\/strong><\/p>\n\n<p>If you want to verify 5G, customize a radio wave shield box, or need product repair, please do not hesitate to contact us about any small matter.<\/p>\n\n<div class=\"wp-block-vk-blocks-grid-column vk_gridColumn\"><div class=\"row\"><div class=\"wp-block-vk-blocks-grid-column-item vk_gridColumn_item col-12 col-sm-12 col-md-12 col-lg-12 col-xl-12 col-xxl-12\"><div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block is-style-shine\"><a href=\"https:\/\/micronix-jp.com\/english\/contact\/\" class=\"vk_button_link btn has-background has-luminous-vivid-orange-background-color btn-lg btn-block\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><i class=\"far fa-envelope vk_button_link_before\" aria-hidden=\"true\"><\/i><span class=\"vk_button_link_txt\"><strong>Contact Form<\/strong><\/span><\/div><\/a><\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Optium tool for analysis of high-frequency circuit design \uff08High-frequency passive probe MP300\uff09 Application MP300 is a passive probe that has a wide frequency range and low input capacitance. It is [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":8207,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"vkexunit_cta_each_option":"","footnotes":""},"categories":[17],"tags":[51,65,76],"class_list":["post-2266","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-category-note","tag-app-rf-device","tag-market-electronic-components","tag-application-test-accessories"],"_links":{"self":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/2266","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/comments?post=2266"}],"version-history":[{"count":1,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/2266\/revisions"}],"predecessor-version":[{"id":7088,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/2266\/revisions\/7088"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media\/8207"}],"wp:attachment":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media?parent=2266"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/categories?post=2266"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/tags?post=2266"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}