{"id":2237,"date":"2011-10-01T00:00:53","date_gmt":"2011-09-30T15:00:53","guid":{"rendered":"https:\/\/micronix-jp.com\/?p=2237"},"modified":"2023-08-01T09:44:51","modified_gmt":"2023-08-01T00:44:51","slug":"me9200_auto","status":"publish","type":"post","link":"https:\/\/micronix-jp.com\/english\/note\/application\/me9200_auto.html","title":{"rendered":"Automatic measurement of ETC electric field strength"},"content":{"rendered":"<p class=\"has-large-font-size\"><strong>It is possible to perform measurement and analysis automatically by merely running the measurement point.<\/strong><\/p><div class=\"wp-block-vk-blocks-table-of-contents-new vk_tableOfContents vk_tableOfContents-style-default tabs\"><div class=\"tab\"><div class=\"vk_tableOfContents_title\">\u76ee\u6b21<\/div><input type=\"checkbox\" id=\"chck1\"\/><label class=\"tab-label vk_tableOfContents_openCloseBtn button_status button_status-close\" for=\"chck1\"><\/label><ul class=\"vk_tableOfContents_list tab_content-close\"><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-2\" data-reactroot=\"\"><a href=\"#vk-htags-d753d117-ff5f-4783-ba68-34234fbc157a\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">1. <\/span>Application<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-2\" data-reactroot=\"\"><a href=\"#vk-htags-647a7b81-b1fc-4497-9fb6-401f98b2e052\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">2. <\/span>Solution<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-3\" data-reactroot=\"\"><a href=\"#vk-htags-e3d570b8-82d9-4c3a-a3e8-acb4aa8911b4\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">2.1. <\/span>PROGRAM FILE<\/a><\/li><li class=\"vk_tableOfContents_list_item vk_tableOfContents_list_item-h-2\" data-reactroot=\"\"><a href=\"#vk-htags-a96ad8a6-b8c8-44fd-8cb0-54b0c3c7447d\" class=\"vk_tableOfContents_list_item_link\"><span class=\"vk_tableOfContents_list_item_link_preNumber\">3. <\/span>Products introduction<\/a><\/li><\/ul><\/div><\/div><h2 class=\"wp-block-heading\" id=\"vk-htags-d753d117-ff5f-4783-ba68-34234fbc157a\">Application<\/h2><p>The amount of information and diversity to be treated on highway are increasing owing to the wireless information technology every year. Not only the fee payment information at ETC toll gate, but also the various informations are treated with such systems as VICS, ITS spot and FF.<\/p><p>When the program measurement mode of an electric field strength measurement system ME9200 is used, the troublesome changes of such as antenna frequency and modulation type during travel are unnecessary.<\/p><p>That is, when the informations of antenna location, frequency and modulation type are inputted into a program file in advance, the measurement and analysis can be automatically performed during travel of a measurement point.<\/p><h2 class=\"vk_block-margin-lg--margin-top wp-block-heading\" id=\"vk-htags-647a7b81-b1fc-4497-9fb6-401f98b2e052\">Solution<\/h2><figure class=\"wp-block-image aligncenter\"><img decoding=\"async\" src=\"\/eng\/image\/application\/ME9200_auto-00.gif\" alt=\"Figure:Measurement point and moving car\"\/><\/figure><h3 class=\"vk_block-margin-md--margin-top wp-block-heading\" id=\"vk-htags-e3d570b8-82d9-4c3a-a3e8-acb4aa8911b4\">PROGRAM FILE<\/h3><p>Measurement start point [km]:20.0<br>Direction:+<\/p><figure class=\"wp-block-flexible-table-block-table\"><table class=\"\"><tbody><tr><th style=\"text-align:center\">No<\/th><th style=\"text-align:center\">Location<\/th><th style=\"text-align:center\">Start[km]<\/th><th style=\"text-align:center\">Zero[km]<\/th><th style=\"text-align:center\">Finish[km]<\/th><th style=\"text-align:center\">Frequency[GHz]<\/th><th style=\"text-align:center\">Modulation<\/th><\/tr><tr><td>1<\/td><td>Measurement Point 1<\/td><td>24.5<\/td><td>24.7<\/td><td>34.8<\/td><td>5.805<\/td><td>QPSK<\/td><\/tr><tr><td>2<\/td><td>Measurement Point 2<\/td><td>37.4<\/td><td>37.6<\/td><td>37.7<\/td><td>5.795<\/td><td>ASK<\/td><\/tr><tr><td>3<\/td><td>Measurement Point 3<\/td><td>31.6<\/td><td>31.8<\/td><td>31.9<\/td><td>5.805<\/td><td>QPSK<\/td><\/tr><\/tbody><\/table><\/figure><h2 class=\"vk_block-margin-lg--margin-top wp-block-heading\" id=\"vk-htags-a96ad8a6-b8c8-44fd-8cb0-54b0c3c7447d\">Products introduction<\/h2><div class=\"wp-block-vk-blocks-select-post-list vk_posts vk_posts-postType-post vk_posts-layout-card-noborder vk_postList\"><div id=\"post-6021\" class=\"vk_post vk_post-postType-product card card-noborder vk_post-col-xs-12 vk_post-col-sm-6 vk_post-col-md-3 vk_post-col-lg-3 vk_post-col-xl-3 vk_post-col-xxl-3 post-2237 post type-post status-publish format-standard has-post-thumbnail hentry category-category-note tag-app-emc tag-market-wireless-communication tag-application-emc\"><div class=\"vk_post_imgOuter\" style=\"background-image:url(https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/me9200_640x640.png)\"><a href=\"https:\/\/micronix-jp.com\/english\/products\/etc\/me9200.html\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/me9200_640x640-300x300.png\" class=\"vk_post_imgOuter_img card-img-top wp-post-image\" alt=\"\" srcset=\"https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/me9200_640x640-300x300.png 300w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/me9200_640x640-150x150.png 150w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/me9200_640x640-100x100.png 100w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/me9200_640x640.png 620w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/div><!-- [ \/.vk_post_imgOuter ] --><div class=\"vk_post_body card-body\"><h5 class=\"vk_post_title card-title\"><a href=\"https:\/\/micronix-jp.com\/english\/products\/etc\/me9200.html\">ETC \/ ITS Spot Electric Field Strength Measurement System ME9200<\/a><\/h5><p class=\"vk_post_excerpt card-text\">ME9200 makes possible to measure the electric field strength of the signal radiated from ETC or ITS spot in a short time. With this system, after measuring the electric field strength distribution of the ETC\/ITS spot with operation wave or CW in a short time, the electric field strength graph and the map diagram are created.<\/p><\/div><!-- [ \/.card-body ] --><\/div><!-- [ \/.card ] --><\/div><p><\/p><div class=\"wp-block-cover is-light vk_block-margin-xl--margin-top\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-white-background-color has-background-dim\"><\/span><img class=\"wp-block-cover__image-background wp-image-8105\" alt=\"\" src=\"https:\/\/micronix-jp.com\/wp-content\/uploads\/2022\/11\/contact_cta_cover.png\" data-object-fit=\"cover\"\/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><p class=\"has-text-align-center has-huge-font-size\"><strong>Please feel free to contact us.<\/strong><\/p>\n\n<p>If you want to verify 5G, customize a radio wave shield box, or need product repair, please do not hesitate to contact us about any small matter.<\/p>\n\n<div class=\"wp-block-vk-blocks-grid-column vk_gridColumn\"><div class=\"row\"><div class=\"wp-block-vk-blocks-grid-column-item vk_gridColumn_item col-12 col-sm-12 col-md-12 col-lg-12 col-xl-12 col-xxl-12\"><div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block is-style-shine\"><a href=\"https:\/\/micronix-jp.com\/english\/contact\/\" class=\"vk_button_link btn has-background has-luminous-vivid-orange-background-color btn-lg btn-block\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><i class=\"far fa-envelope vk_button_link_before\" aria-hidden=\"true\"><\/i><span class=\"vk_button_link_txt\"><strong>Contact Form<\/strong><\/span><\/div><\/a><\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>It is possible to perform measurement and analysis automatically by merely running the measurement point.ApplicationThe amount of information and diversity to be treated on highway are increasing owing to the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":8182,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"vkexunit_cta_each_option":"","footnotes":""},"categories":[17],"tags":[44,68,71],"class_list":["post-2237","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-category-note","tag-app-emc","tag-market-wireless-communication","tag-application-emc"],"_links":{"self":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/2237","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/comments?post=2237"}],"version-history":[{"count":4,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/2237\/revisions"}],"predecessor-version":[{"id":9600,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/2237\/revisions\/9600"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media\/8182"}],"wp:attachment":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media?parent=2237"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/categories?post=2237"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/tags?post=2237"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}