{"id":2191,"date":"2013-08-01T00:00:52","date_gmt":"2013-07-31T15:00:52","guid":{"rendered":"https:\/\/micronix-jp.com\/?p=2191"},"modified":"2023-03-20T17:22:40","modified_gmt":"2023-03-20T08:22:40","slug":"zigbee_ieee","status":"publish","type":"post","link":"https:\/\/micronix-jp.com\/english\/note\/application\/zigbee_ieee.html","title":{"rendered":"Simple test of the Radio Law and IEEE on ZigBee module"},"content":{"rendered":"\n<p class=\"bigTitle\" style=\"margin-bottom: 1em\">System for simple test of the Radio Law and IEEE utilizing a real time spectrum analyzer<\/p>\n\n\n<h2>Application<\/h2>\n<p>RF transmission characteristic test of equipment with built-in antenna, which is regulated  in the technical standard conformity certification and IEEE, can be easily measured combining real time spectrum analyzer MSA500 series and anechoic box. By limiting specifications or applications, it is possible to construct an inexpensive system. <\/p>\n<p>The physical layer test of ZigBee is regulated in the technical standard conformity certification and IEEE802.15.4-2003.<\/p>\n\n\n\n<h2>Solution<\/h2>\n<h3>Test contents of the technical standard conformity certification \uff08reference\uff09<\/h3>\n<ol>\n<li>Frequency deviation<\/li>\n<li>Occupied and spread bandwidth<\/li>\n<li>Spurious radiation strength<\/li>\n<li>Transmission power<\/li>\n<li>Limit on secondary radiated emission<\/li>\n<li>Angular width of main radiation of antenna<\/li>\n<li>Interference prevention function<\/li>\n<\/ol>\n\n<h3>Test contents of IEEE \uff08reference\uff09<\/h3>\n<ol>\n<li>Spectrum mask test<\/li>\n<li>EVM\uff08Error vector magnitude\uff09<\/li>\n<li>Carrier frequency error<\/li>\n<li>Spurious radiation strength<\/li>\n<li>Transmission power<\/li>\n<\/ol>\n\n<p>Note. * MSA500 series doesn't have the modulation analysis function. <\/p>\n\n<h3>Connection example<\/h3>\n<img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/application\/ZigBee_ieee-00.jpg\" alt=\"Figure:Connection example\" width=\"730\" height=\"232\">\n\n<h3> Example of Ch15 (2480MHz)<\/h3>\n\n<div style=\"margin-bottom: 2em\">\n  <p><img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/application\/ZigBee_ieee-01.gif\" alt=\"Photo:Reference example of CH15 (2480 MHz) Part1\" width=\"649\" height=\"420\"><\/p>\n\t<p>\n  <img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/application\/ZigBee_ieee-02.gif\" alt=\"Photo:Reference example of CH15 (2480 MHz) Part2\" width=\"645\" height=\"418\"><\/p>\n  <p>In the measurement of \"spurious radiation strength\" and \"limit on secondary radiated emission\", a spectrum analyzer with 12.5GHz or more bandwidth is required. However, MSA500 series is utilizable if limited by third harmonic (7.4 GHz).<br>\n*Measuring frequency range of MSA558\uff1a20kHz to 8.5GHz<\/p>\n<\/div>\n  \n  <div style=\"margin-bottom: 2em\"><img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/application\/ZigBee_ieee-03.gif\" alt=\"Photo:Reference example of CH15 (2480 MHz) Part3\" width=\"649\" height=\"420\">\n<p>\"EVM\" and \"frequency carrier error\" can't be measured since the modulation analysis function isn't installed.  However, it is possible to observe the raw constellation waveform of Offset-QPSK modulation.<\/p>\n<\/div>\n  \n  <div style=\"margin-bottom: 2em\"><img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/application\/ZigBee_ieee-04.gif\" alt=\"Photo:Reference example of CH15 (2480 MHz) Part4\" width=\"644\" height=\"417\">\n<p>Example of \"Occupied bandwidth\" required by the Radio Law<\/p>\n<\/div>\n  \n  <div style=\"margin-bottom: 2em\"><img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/application\/ZigBee_ieee-05.gif\" alt=\"Photo:Reference example of CH15 (2480 MHz) Part5\" width=\"645\" height=\"416\">\n<p>Example of \"Spread bandwidth\" required by the Radio Law<\/p>\n<\/div>\n\n\n\n\n<h2>System configuration<\/h2>\n<table>\n<tbody>\n<tr>\n<td><a href=\"\/english\/products\/spectrum-analyzer\/msa500\/msa558.html\">Handheld signal analyzer MSA558 <\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"\/english\/products\/shield-box\/taurus\/my1530.html\">Electromagnetic anechoic box \/ MY1530 \uff0b I\/F module <\/a><\/td>\n<\/tr>\n<tr>\n<td>Others, Antenna, cables and adapter<\/td>\n<\/tr>\n<\/tbody>\n<tfoot>\n<\/tfoot>\n<\/table>\n\n\n\n<h2>Products introduction<\/h2>\n[products skus=\"msa558,my1530,if-module\" orderby=\"date\" order=\"asc\" columns=\"3\"]\n\n\n\n<div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block\"><a href=\"\/eng\/file-download\/application\/pdf\/zigbee_ieee.pdf\" style=\"background-color:#5b6069;border:1px solid #5b6069;color:#fff;\" class=\"vk_button_link btn btn-md btn-block white\" role=\"button\" aria-pressed=\"true\" target=\"_blank\"  rel=\"noopener\"><i class=\"fas vk_button_link_before fa-file-pdf\"><\/i><span class=\"vk_button_link_txt\">Download This Application Note (PDF) <\/span><\/a><\/div>\n\n\n\n<p><\/p>\n\n<div class=\"wp-block-cover is-light vk_block-margin-xl--margin-top\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-white-background-color has-background-dim\"><\/span><img class=\"wp-block-cover__image-background wp-image-8105\" alt=\"\" src=\"https:\/\/micronix-jp.com\/wp-content\/uploads\/2022\/11\/contact_cta_cover.png\" data-object-fit=\"cover\"\/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<p class=\"has-text-align-center has-huge-font-size\"><strong>Please feel free to contact us.<\/strong><\/p>\n\n\n\n<p>If you want to verify 5G, customize a radio wave shield box, or need product repair, please do not hesitate to contact us about any small matter.<\/p>\n\n\n\n<div class=\"wp-block-vk-blocks-grid-column vk_gridColumn\"><div class=\"row\">\n<div class=\"wp-block-vk-blocks-grid-column-item vk_gridColumn_item col-12 col-sm-12 col-md-12 col-lg-12 col-xl-12 col-xxl-12\">\n<div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block is-style-shine\"><a href=\"https:\/\/micronix-jp.com\/english\/contact\/\" class=\"vk_button_link btn has-background has-luminous-vivid-orange-background-color btn-lg btn-block\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><i class=\"far fa-envelope vk_button_link_before\" aria-hidden=\"true\"><\/i><span class=\"vk_button_link_txt\"><strong>Contact Form<\/strong><\/span><\/div><\/a><\/div>\n<\/div>\n<\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>System for simple test of the Radio Law and IEEE utilizing a real time spectrum analyzer Application RF transmission characteristic test of equipment with built-in antenna, which is regulated in [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":8176,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"sns_share_botton_hide":"","vkExUnit_sns_title":"","_vk_print_noindex":"","sitemap_hide":"","_veu_custom_css":"<!--\u8a18\u4e8b\u306e\u30a2\u30a4\u30ad\u30e3\u30c3\u30c1\u3092\u6d88\u3059-->\n.veu_autoEyeCatchBox{\ndisplay:none;\n}","veu_display_promotion_alert":"","vkexunit_cta_each_option":"","_lightning_design_setting":{"layout":"default"},"header_top_description":"","footnotes":""},"categories":[17],"tags":[68,73,75],"class_list":["post-2191","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-category-note","tag-market-wireless-communication","tag-application-shield-box","tag-application-spectrum-analyzer"],"acf":[],"veu_head_title_object":{"title":"","add_site_title":""},"_links":{"self":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/2191","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/comments?post=2191"}],"version-history":[{"count":1,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/2191\/revisions"}],"predecessor-version":[{"id":7054,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/2191\/revisions\/7054"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media\/8176"}],"wp:attachment":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media?parent=2191"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/categories?post=2191"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/tags?post=2191"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}