{"id":1809,"date":"2006-10-05T00:00:51","date_gmt":"2006-10-04T15:00:51","guid":{"rendered":"https:\/\/micronix-jp.com\/?p=1809"},"modified":"2023-03-20T17:09:40","modified_gmt":"2023-03-20T08:09:40","slug":"mr2300-1eng","status":"publish","type":"post","link":"https:\/\/micronix-jp.com\/english\/tech\/technology\/mr2300-1eng.html","title":{"rendered":"Good way to master the EMI precompliance test system"},"content":{"rendered":"<h2>Abstract<\/h2>\n<p> As for the EMI test, it is evaluated whether the radiated emission or the conducted emission discharged from EUT (Equipment Under Test) exceeds the limit value set beforehand. <\/p>\n<p>This test is generally done at the formal EMI test site equipped with the anechoic chamber. It seems to be actual that much waiting time and cost are needed there and longer time and more cost are wasted there when it is repeated many times to solve the problem and to test formally.<\/p>\n<p>The EMI total test system MR2300, which focuces on being used to solve the problem in advance \u226aPrecompliance\u226b and reducing the number of times of formal test to one or two times, is introduced in this site. <\/p>\n<h2>EMI total test system<\/h2>\n<p> MR2300 is a complete and total test system including not only a compact broadband antenna, a spectrum analyzer for EMI, LISN and PC software for EMI but also an anechoic box.<\/p>\n<p> The system configuration of MR2300 is shown in Fig.1. <\/p>\n<p> This system can do\n<\/p><ol>\n<li>the radiated emission measurement in the frequency range 30MHz to 3GHz by using an anechoic box and a broadband antenna<\/li>\n<li>the conducted emission measurement in the frequency range 150kHz to 30MHz by using LISN.<\/li>\n<\/ol>\n<p><\/p>\n<p> Moreover, the measurement values on the screen of a computer can be directly read because Spectrum analyzer for EMI MSA338E and PC software MAS230 correct the frequency characteristics of the antenna gain, the conversion into 3 meters in measurement distance and the attenuation of LISN. <\/p>\n<p> Therefore, the user can easily do the EMI test. <\/p>\n<div class=\"Center\"> <img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/technology\/MR2300-1Eng-00.gif\" alt=\"Fig.1:System  configuration  of MR2300\" width=\"680\" height=\"316\">\n<p style=\"margin-bottom:4em\">Fig.1:System  configuration  of MR2300<\/p>\n<img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/technology\/MR2300-1Eng-01.png\" alt=\"Fig.2:PC software MAS230 \" width=\"600\" height=\"477\">\n<p>Fig.2:PC software MAS230 <\/p>\n<\/div>\n<h2>Test example<\/h2>\n<p>A few important points about the measurement are described as follows as an example of the radiated emission test of a keyless entry of a car. <\/p>\n<h3>1. Installation of EUT into anechoic box<\/h3>\n<p>The installation requirement of EUT in the anechoic box MY5310 is shown in Fig.3. <\/p>\n<p>The noise in all directions radiated from EUT cannot be detected with the broadband antenna MAN101. <\/p>\n<p>The detection of the radiated noise of the component based on the following conditions becomes possible.<\/p>\n<ul>\n<li> The noise should be vertical and linear polarization component. <\/li>\n<li>The noise should be a component being radiated toward a broadband antenna from EUT. <\/li>\n<li>The noise should be a component being radiated from the upper position of the ground plate.<\/li>\n<\/ul>\n<p>In short, only the noise being radiated from the circle mark in Fig.3 can be measured and evaluated. <\/p>\n<p>Fig.2  PC software MAS230 The EUT as an example is put on the styrene foam that is non-conductive as shown in Photo 1 because the size is small and the position put is lower than the ground plate.<\/p>\n<p>The position in which the radiated noise becomes maximum is found by rotating the knob for turntable by hand power.<\/p>\n<p>In  addition,  regarding  the  horizontal  polarization component, the measurement should be done by rotating EUT because the antenna cannot be moved.<\/p>\n<div class=\"Center\"> <img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/technology\/MR2300-1Eng-03.png\" alt=\"Photo1:Installation  \nof EUT(keyless entry)\" width=\"508\" height=\"381\">\n<p style=\"margin-bottom:4em\">Photo1:Installation  \nof EUT(keyless entry)<\/p>\n<img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/technology\/MR2300-1Eng-04.gif\" alt=\"Fig.3:Installation requirement of EUT\" width=\"400\" height=\"220\">\n<p>Fig.3:Installation requirement of EUT<\/p>\n<\/div>\n<h3>2. Measurement by PC software<\/h3>\n<p>The EMI measurement can be easily done only by clicking RUN\/STOP in the automatic measurement mode because the parameters recommended are set in Spectrum analyzer MSA338E and PC software MAS230 beforehand.<\/p>\n<p>The frequency span is divided into three bands of Wide, Middle and Narrow for shortening the measurement time in this software.<\/p>\n<ul>\n<li>In the Wide span, the measurement is done with PK detection in the whole mesuring frequency range and then the spectrums out of specification are searched.<\/li>\n<li>In the Middle span, only the above spectrums out of specification are measured with PK detection and the spectrums out of specification are searched as well.<\/li>\n<li>In the Narrow span, only the above spectrums out of specification are measured with QP or AV detection.<\/li>\n<\/ul>\n<p>The measurement result of EUT is shown in Fig.4. The noise out of specification is displayed on the screen as the numeric data with the spectrum waveform.<\/p>\n<p>The measurement result shown in Fig.4 is by the automatic measurement but PC software also has the manual measurement mode. This mode is very convenient for debugging EUT and removing the  disturbance noise.<\/p>\n<div class=\"Center\"> <img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/technology\/MR2300-1Eng-05.gif\" alt=\"Fig.4 Example of measurement result of EUT\" width=\"600\" height=\"394\">\n<p>Fig.4 Example of measurement result of EUT<\/p>\n<\/div>\n<h2> Comparison of MR2300 and formal test site <\/h2>\n<ol>\n<li>Each advantage and disadvantage of MR2300 and formal test site are shown in Table1. <\/li>\n<li>Comparison with data at anechoic chamber.<\/li>\n<\/ol>\n<p>Table1 Advantages and disadvantages of MR2300 <\/p>\n<style>\ntable th{\n  text-align: center;\n}\n<\/style>\n<table>\n<tbody><tr>\n<th><\/th>\n<th>MR2300<\/th>\n<th>Formal test site<\/th>\n<\/tr>\n<tr>\n<th>Cost<\/th>\n<td>The system price is very cheap.  Moreover, the running cost can be  saved because the problems can be solved before a formal test. The  occupation area is also narrow. <\/td>\n<td>In case of renting a formal test site, the rental fee is thousands dollars a day. In case of  constructing an anechoic chamber, the huge  construction cost of about one million dollars is necessary, and the big site is also necessary. <\/td>\n<\/tr>\n<tr>\n<th>Efficiency<\/th>\n<td>It is possible to proceed to the step of the problem\u2019s solution at once. Also released from the restriction of a place and time. <\/td>\n<td>It is difficult to proceed to the step of the problem\u2019s solution at once because of making reservation, and long travel time is also necessary when the site exists far. <\/td>\n<\/tr>\n<tr>\n<th>Performance<\/th>\n<td>Not approved formally.<\/td>\n<td>Approved formally.<\/td>\n<\/tr>\n<\/tbody><\/table>\n<div class=\"Center\" style=\"margin-top:2em\"> <img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/technology\/MR2300-1Eng-07.gif\" alt=\"Fig.5:Measurement result by anechoic chamber\" width=\"378\" height=\"292\">\n<p>Fig.5:Measurement result by anechoic chamber<\/p>\n<\/div>\n<div class=\"Center\" style=\"margin-top:2em\"> <img loading=\"lazy\" decoding=\"async\" src=\"\/eng\/image\/technology\/MR2300-1Eng-06.gif\" alt=\"Fig.6:Measurement result by MR2300\" width=\"600\" height=\"386\">\n<p>Fig.6:Measurement result by MR2300<\/p>\n<\/div>\n<p>Fig.5 and Fig.6 show the result of measuring the noise, which is radiated from CNE (Comparison Noise Emitter) widely used for the calibration of anechoic chamber, in the anechoic chamber and in the MR2300. <\/p>\n<p>The measurement result in MR2300 was almost the same as in the anechoic chamber as judged from Fig.5 and Fig.6 although there is a physical restriction in MR2300 because broadband antenna, anechoic box, spectrum analyzer and PC software have been developed overall. <\/p>\n<h2>Conclusions<\/h2>\n<p>As explained in this paper, the EUT may pass the formal test by one time if the sufficient check is done by MR2300 system in advance. Moreover, even if the EUT fails in the formal test, the problem will be solved in a short time by using MR2300 and the result of the formal test. <\/p>\n<p>In conclusion, the development cost and time can be greatly reduced by using the EMI total test system MR2300 well as a debugging tool to solve the noise problem.<\/p>\n\n<section>\n<h2>Products introduction<\/h2>\n<div class=\"woocommerce \"><ul class=\"products columns-4\">\n<li class=\"product type-product post-5951 status-publish first instock product_cat-shop-category-emc-test-system product_tag-tag-emi-test-system has-post-thumbnail shipping-taxable product-type-simple\">\n\t<a href=\"https:\/\/micronix-jp.com\/english\/products\/emc\/mr2300.html\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/MR2300_620x620-300x300.png\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"\" srcset=\"https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/MR2300_620x620-300x300.png 300w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/MR2300_620x620-150x150.png 150w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/MR2300_620x620-100x100.png 100w, https:\/\/micronix-jp.com\/english\/wp-content\/uploads\/sites\/2\/2023\/03\/MR2300_620x620.png 620w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><h2 class=\"woocommerce-loop-product__title\">Pre-compliance EMI test system MR2300<\/h2>\n<\/a><\/li>\n<\/ul>\n<\/div>\n<\/section><div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block\"><a href=\"\/eng\/file-download\/technical\/pdf\/MR2300-1Eng.pdf\" style=\"background-color:#726756;border:1px solid #726756;color:#fff;\" class=\"vk_button_link btn btn-md btn-block white\" role=\"button\" aria-pressed=\"true\" target=\"_blank\"  rel=\"noopener\"><i class=\"fas vk_button_link_before fa-file-pdf\"><\/i><span class=\"vk_button_link_txt\">Download This Technical Report (PDF) <\/span><\/a><\/div><p><\/p><div class=\"wp-block-cover is-light vk_block-margin-xl--margin-top\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-white-background-color has-background-dim\"><\/span><img class=\"wp-block-cover__image-background wp-image-8105\" alt=\"\" src=\"https:\/\/micronix-jp.com\/wp-content\/uploads\/2022\/11\/contact_cta_cover.png\" data-object-fit=\"cover\"\/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><p class=\"has-text-align-center has-huge-font-size\"><strong>Please feel free to contact us.<\/strong><\/p>\n\n<p>If you want to verify 5G, customize a radio wave shield box, or need product repair, please do not hesitate to contact us about any small matter.<\/p>\n\n<div class=\"wp-block-vk-blocks-grid-column vk_gridColumn\"><div class=\"row\"><div class=\"wp-block-vk-blocks-grid-column-item vk_gridColumn_item col-12 col-sm-12 col-md-12 col-lg-12 col-xl-12 col-xxl-12\"><div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-block is-style-shine\"><a href=\"https:\/\/micronix-jp.com\/english\/contact\/\" class=\"vk_button_link btn has-background has-luminous-vivid-orange-background-color btn-lg btn-block\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><i class=\"far fa-envelope vk_button_link_before\" aria-hidden=\"true\"><\/i><span class=\"vk_button_link_txt\"><strong>Contact Form<\/strong><\/span><\/div><\/a><\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Abstract As for the EMI test, it is evaluated whether the radiated emission or the conducted emission discharged from EUT (Equipment Under Test) exceeds the limit value set beforehand. This [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":8262,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"vkexunit_cta_each_option":"","footnotes":""},"categories":[32],"tags":[79],"class_list":["post-1809","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-category-technology","tag-technology-emc"],"_links":{"self":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/1809","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/comments?post=1809"}],"version-history":[{"count":1,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/1809\/revisions"}],"predecessor-version":[{"id":6977,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/posts\/1809\/revisions\/6977"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media\/8262"}],"wp:attachment":[{"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/media?parent=1809"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/categories?post=1809"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/micronix-jp.com\/english\/wp-json\/wp\/v2\/tags?post=1809"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}